Avec la passerelle mbGate PB, nous pouvons désormais intégrer jusqu’à 2 segments PROFIBUS PA et 1 segment PROFIBUS DP à un système de controle Modbus TCP. La passerelle agit comme un serveur Modbus TCP  et un maitre PROFIBUS. Avec cette gateway, le cout de l’intégration est considérablement réduit.  Elle permet la paramétrisation et l’utilisation des outils standard de management.

Key Component for Transition to State-of-the-Art Technology

  • Simple replacement of installed PROFIBUS DP/PA segment couplers
  • Re-use of existing PROFIBUS segments without requiring modification

Direct Connectivity to PROFIBUS Segments

  • Single access point to PROFIBUS DP and PROFIBUS PA segments from Modbus TCP networks
  • Acting as Modbus TCP Server and PROFIBUS PA and PROFIBUS DP Master
  • Support of one PROFIBUS DP segment and up to two PROFIBUS PA segments

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Supports major Modbus engineering tools such as Schneider Unity Pro or Siemens TIA Portal
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM

MODBUS/TCP Redundancy

  • Supports the use of two redundant PLCs and two redundant gateways
  • Easily enabled via licensing
  • Full control of redundant operation mode via engineering and PLC
Scope of Delivery
HardwarembGate PB Gateway
DocumentationOn Website
Order Numbers
GCA-EN-024808mbGate PB, Modbus TCP to PROFIBUS Gateway. Supports 2 PA segments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).
Additional Products and Services
LRA-EN-024851gatePlus HighAvailability, License for activating redundancy features in mbGate PB
LRL-DY-134501dataFEED OPC Suite, Version 4.01 and higher, including all supported PLC protocols, support for OPC UA, access for any number of dataFEED OPC Tunnel Clients, for simultaneous access to a total of up to 100 OPC UA Servers, OPC Servers and OPC Tunnel Servers, and many more Functionalities such as Database and File Access, Data Exchange, Optimizer, Concentrator and Bridge
GCA-EL-024802mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 2 PA segments (up to 32 PA devices).
GCA-EL-024804mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 4 PA segments (up to 64 PA devices).
GCA-EN-024806mbGate DP, Modbus TCP to PROFIBUS DP Gateway. Supports 1 PROFIBUS DP segment (RS485).

Video Channel : Retrouvez nous sur notre page channel YOUTUBE 

Logiciel datacheck analyzer : pour diagnostic Ethernet industriel

Analyzer IE / PRO

Software for Mobile Diagnostics and Acceptance Testing of Industrial Networks

Analyzer IE / PRO is a comprehensive software solution for acceptance testing and efficient troubleshooting of Ethernet-based industrial communication. In a PROFINET environment, the mobile diagnostic tool generates standardized acceptance reports in accordance with the recommendations of PROFIBUS & PROFINET International (PI), making it an easy-to-use product that is tailored to the needs of plant suppliers, maintenance personnel as well as service providers.

Comprehensive Functionality

  • Diagnostics list, error statistics, network statistics
  • Enhanced flexibility by supporting online as well as offline mode
  • Generation, analysis and handling of diagnostic data such as graphical topology, inventory list and reference measurements, also for standard Ethernet components (eg PCs, camera systems)

Automated Generation of Acceptance Test Documents

  • Time saving by automatically created test reports
  • Flexible definition of acceptance criteria
  • Transparent reporting by following PI guidelines

Tool Addressing Complete Plant Lifecycle

  • Data on network configuration, network communication and diagnostic messages
  • Error identification for effective troubleshooting (e.g. based on inventory list of network devices)
  • Chance to support exchange of general project information between end users, EPC contractors, system integrators and maintenance service providers
  • Seamless integration with Softing diagnostics per-manent monitoring solutions TH SCOPE and TH LINK
Technical Data
Functionality
  • Analysis of device logs
  • Live list, statistics, inventory
  • Topology and trend analysis
  • GSDML file support, plaintext messages in diagnostic list
  • Acceptance measurements and acceptance reports
  • Reference comparison
  • Configurable time intervals for automated export of inventory and topology data
  • Data export via Excel
  • Configurable Blacklist feature for robust operation
  • Optional (Analyzer PRO): Telegram analysis: jitter, refresh interval, load ratio
Supported ProtocolsPROFINET, EtherNet/IP, Modbus TCP
Interfaces
  • SNMP Agent
  • OPC UA Server
System RequirementsAdobe Reader 8 or higher for reading the documentation and for printing the topology
Supported Operating SystemsWindows 7, Windows 8.1, Windows 10
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016
Network AccessData collection through TH LINK PC (PROFINET, EtherNet/IP, Modbus TCP)
Demo VersionFull TH SCOPE functionality can be used for free for 30 days after installation
LicensingSoftware or hardware key
Scope of Delivery
SoftwareAnalyzer IE
LicenseSoftware key (bound to PC) or hardware key
HardwareprofiTap: Network tap for telegram analysis operation, optional (Analyzer PRO)
DocumentationInstallation manual, user manual, release note
Order Numbers
LRA-JY-003041Analyzer IE (software key)
LRL-JY-003042Analyzer IE (hardware key)
KPL-JY-003043Analyzer PRO
Additional Products and Services
GEA-JN-003006TH LINK PROFIBUS
GDA-JA-003034TH LINK PROFINET
GDA-JY-003037TH LINK Industrial Ethernet
LRA-JY-003028TH LINK PC Industrial Ethernet
TRA-PB-TECHTraining “PROFIBUS Technology”
TRA-PB-TSTraining “PROFIBUS Troubleshooting with exam to Certified PROFIBUS Installer”
TRA-PN-CERTINSTTraining “PROFINET Acceptance and Commissioning”
TRA-PN-CERTENGTraining “PROFINET Technology graduated as Certified PROFINET Engineer”
TRA-PN-TOOLSOn-site training: PROFINET tools

Pour les formations, veuillez nous contacter

Les personnes intéressées par ce produit, peuvent être aussi interessées par :

 

THScope ( Logiciel )

Management and Diagnostics for Industrial Networks

TH SCOPE is a software product for industrial network management and network diagnostics. Geared to plant operators and maintenance personnel, TH SCOPE is an all-in-one, easy-to-use solution for permanent monitoring and predictive maintenance, for acceptance testing and for troubleshooting. Combined with TH LINK components, the product supports PROFIBUS, PROFINET, EtherNet/IP and Modbus TCP protocols.
The PROFINET Commissioning Report functionality is now available in new THSCOPE Release. Download the new THSCOPE under ‘Downloads’ section.
csm_THScope_D_EN_160401_300_9e86a142a3

Versatile Solution for a Wide Variety of Diagnostics Applications

  • Network commissioning, acceptance testing
  • Stationary operation for continuous monitoring
  • Fault localization and identification in case of failure

Comprehensive Representation and Analysis of Diagnostic Data

  • Data on network communication (e.g. load, error statistics)
  • Data from network configuration (e.g. device names, firmware versions, topology)
  • Diagnostic messages (network and device diagnostics)
  • Data collection also from standard Ethernet devices (e.g. PCs or camera systems)

Optimized for Maintenance Users

  • Easy and intuitive handling and operation
  • No expert knowledge of IT or networks required
  • Support of various network protocols (PROFIBUS, PROFINET, EtherNet/IP, Modbus TCP)

Flexible Integration into Existing Systems and Processes

  • Integration of network data into monitoring tools and supervisory control systems via SNMP or OPC
  • Export of all diagnostic data, support of further processing in applications such as Excel
  • Web-based access, local or remote
Functionality
  • Network overview with network and device status plus diagnostic messages with troubleshooting recommendations
  • Analysis of device logs
  • Live list, statistics, inventory
  • GSDML file support, plaintext messages in diagnostic list
  • Topology and trend analysis
  • Automatic e-mail notification in case of fault
  • Reference comparison
  • Acceptance measurements and acceptance reports
  • Data export via Excel
Supported ProtocolsPROFIBUS (TH SCOPE V2.2),
PROFINET, EtherNet/IP, Modbus TCP (TH SCOPE V2.2 and TH SCOPE V3.0)
Interfaces
  • SNMP Agent
  • OPC Classic DA Server
System Requirements
  • Web browser with Adobe Flash Player 14 or higher
    (for TH SCOPE V2.2, not required for TH SCOPE V3.0)
  • Adobe Reader 8 or higher for reading the documentation and for printing the topology
Supported Operating SystemsWindows 7, Windows 8, Windows 8.1,
Windows Server 2008, Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2
Network AccessData collection through TH LINK (PROFIBUS, PROFINET, EtherNet/IP, Modbus TCP and Industrial Ethernet)
Demo VersionFull TH SCOPE functionality can be used for free for 30 days after installation
LicensingVia software or hardware key
 Scope of Delivery
SoftwareTH SCOPE (by download from Softing‘s website)
LicenseSoftware or hardware key
DocumentationInstallation Manual, User Manual, Release Note
Order Numbers
ATV-LRA-JY-003024TH SCOPE (software key)
ATV-LRL-JY-003025TH SCOPE (hardware key)
Additional Products and Services
ATV-GEA-JN-003006TH LINK PROFIBUS
ATV-GDA-JA-003034TH LINK PROFINET
ATV-GDA-JY-003037TH LINK Industrial Ethernet
ATV-LRA-JY-003028TH LINK PC Industrial Ethernet

TH SCOPE:
If your network is protected by a second firewall in addition to the Windows firewall, make sure that the following settings are made to allow TH SCOPE services to communicate properly.

  • Enabling of HTTP port 80 – inbound and outbound
  • Enabling of SNMP port 161 inbound or port 2367 (if port 161 is used by another SNMP agent).
  • Enabling of IP 224.0.5.128 port 2364 UDP outbound
  • Enabling of UDP ports 2365 outbound and 2366 inbound

 

The following ports are used by TH SCOPE for internal communication only:

  • Port 22
  • Port 80
  • Port 1100
  • Ports 1123 – 1151
  • Port 1500
  • Port 1501
  • Ports 2363 – 2366
  • Ports 49152 – 49171

People interested in this product, can be interested in :

THLink – Industrial Ethernet

Outil de diagnostic : Industrial Ethernet, indépendant du contrôleurs

Le THLink Industrial Ethernet, permet le contrôle et le diagnostic des réseaux PROFINET, MODBUS TCP et ETHERNET/IP. Les données sont collectées sur un réseua de 254 noeuds et  rendent disponibles ses données via le logiciel  THSCOPE. le THLINK Industrial Ethernet est facile à utiliser et peut être intégré sans interférer avec une installation existante

csm_THLink_IE_D_EN_170101_311_fbdb7e6c27

THLink Industrial Ethernet for an independent Access to PROFINET, EtherNet/IP and Modbus TCP Networks

  • Controller-independent
  • Independent of configuration tools
  • Only one tool needed to monitor multiple IP subnetworks (up to 254 nodes, one or more controllers

THLink Industrial Ethernet has been designed for Installation without Interference with Plant Operation

  • Connection to free port in industrial network, also possible during operation of the plant
  • No need to install TAPs or use mirror ports
  • Highest security (separate accesses for control room level and plant level, no routing)
  • Easy integration into existing plants thanks to compact design

Powerful Data Collection Capabilities Optimized for Ethernet-Based Industrial Communication

  • Support of the PROFINET, EtherNet/IP and Modbus TCP protocols
  • Collection also from standard Ethernet devices (e.g. PCs or camera systems)
  • PROFINET supervisor in PROFINET networks
  • Network load limit according to PROFINET guidelines

Optimized for Use by Maintenance Engineers, thanks to the THLink industrial Ethernet

  • Suitable for network acceptance testing, continuous monitoring and troubleshooting
  • Easy and intuitive handling and operation
  • Fault identification with intelligent troubleshooting assistance
  • Seamless integration with TH SCOPE diagnostics software
Functionality
  • Network detection and data collection
  • Alarm notification in case of fault
  • Basic monitoring, configuration
  • Integrated web server
Input Voltage24 VDC (18 VDC … 32 VDC)
Current consumptionmax. 180 mA
Current consumption relay contactmax. 100 mA
Operating Temperature-40 °C … +75 °C
Relative Air Humidity5 … 95 % (no condensation)
Ethernet PortsRJ-45 (10Base-T/100Base-TX)
Supported SD CardsSee Release Notes
Mounting35 mm DIN rail
Dimensions (HxWxD)22.5 x 99 x 114.5 mm
Weight120 g
CertificationsCE
GDA-JY-003037TH LINK Industrial Ethernet

Scope of Delivery

HardwareTH LINK Industrial Ethernet
DocumentationInstallation Manual, Release Note (by download)

Additional Products and Services

ATV-LRA-JY-003024TH SCOPE (software key)
ATV-LRL-JY-003025TH SCOPE (hardware key)
ATV-LRA-JY-003028TH LINK PC Industrial Ethernet (software key)
ATV-LRL-JY-003029TH LINK PC Industrial Ethernet (hardware key)
ATV-TRA-PN-TECHTraining “PROFINET Technology”
ATV-TRA-PN-CERTENGTraining “PROFINET Commissioning and Troubleshooting”

dataFEED uaGate MB

dataFEED uaGate Modbus TCP

Passerelle pour OPC UA et communication MQTT vers PLCs Modbus TCP

  • Fonctionalité de communication OPC UA
  • Import des symboles utilisant les données du contrôleur via interface web ?
  • Haute protection assurée pour le transfert des données

Accès des données Modbus de votre PLC pour les applications OPC UA

  • Accès aux contrôleurs Modbus, ex:.  Schneider Electric, Wago, Beckhoff, Phoenix Contact, etc….
  • Intégration complète dans les systèmes de “Managements” comme : ERP, MES ou SCADA utilisant un serveur OPC UA, fournissant une plateforme indépendante fiable et sécurisée.
  • Accès aux données locales et globales facile et intégration facile et rapide à travers les pare-feux
  • Spécialement conçu pour des mises à jours de systèmes vieillissant et limitant ainsi, les investissements lourds.
  • Pas besoin de mise à jours logiciel, opérating systems, ce qui limite les risques de “crash” à long terme.
  • Programmation PLC minimale pour la configuration des registres
  • Pas besoin de PC dédié

Données de projets PLC disponibles pour utilisation spécifique

  • Import des symboles depuis fichier TXT
  • Installation simple et facile du serveur OPC, qui ne demande que quelques étapes pour l’accès des données PLC Modbus
  • Interface “Web-based” pour la configuration

Sécurité de type industriel “maximale”

  • Séparation physique des interfaces et séparations des droits pour les réseaux OT et IT.
  • Supportant les standards de sécurité tel que : SSL/TLS et certificats X.509
  • Encryption des données au standard OPC UA et authentification des utilisateurs
  • Securité supportée pour la communication MQTT avec cléf privée et ” clouds ” publics
HardwareProcessorAltera Cyclone V SoC with Dual-core ARM Cortex-A9
Connectors2 x IEEE 802.3 100BASE-TX/10BASE-T (independent interfaces)
Status LEDsPWR (power supply), RUN (running), ERR (error), SYS (configuration)
Dimensions (H x W x D)100 mm x 22.5 mm x 105 mm
Power Supply18 VDC … 32 VDC, SELV/PELV supply mandatory Typically 200 mA, maximum 1 A at switch-on
Operating Temperature, Horizontal DIN Rail Installation-40 °C .. 50 °C (0 mm minimum distance)
-40 °C .. 55 °C (22.5 mm minimum distance)
Operating Temperature, Vertical DIN Rail Installation-40 °C .. 35 °C (0 mm minimum distance)
-40 °C .. 40 °C (22.5 mm minimum distance)
Storage Temperature-40 °C .. 85 °C
Relative Humidity10 % … 90 %, non-condensing
WeightAbout 0.2 kg
MountingDIN Rail (35 mm)
HousingPhoenix Contact ME MAX
Protection ClassIP20
SoftwareProtocolsModbus TCP, OPC UA (Server, 20,000 items in total), MQTT (Publisher, up to 1,000 topics)
Supported ControllersModbus TCP controllers, e.g. from Schneider Electric, Wago, Beckhoff, Phoenix Contact, etc.
ConformityEmissionEC Directive 2004/108/EC “Electromagnetic Compatibility”, EN 55011, Group 1, Class A
EC Directive 2004/108/EC “Electromagnetic Compatibility”, EN 55022, Class A
EC Directive 2004/108/EC “Electromagnetic Compatibility”, EN 61000, Part 6-4
FCC CFR45, Part 15 Section 15.107 and 15.109 (Class A),
VCCI Class A Information Technology Equipment 2002
ImmunityEC Directive 2004/108/EC “Electromagnetic Compatibility”, EN 61000, Part 6-2
ATV-GAA-YE-145133uaGate MB

Scope of Delivery

HardwareuaGate MB
SoftwareTool for configuration over integrated web interface
DocumentationQuick Startup Guide (printed documentation)

Les personnes intéressées par ce produit peuvent être intéressées par le produit suivant :

echocollect -e

La passerelle echocollect -e

La passerelle Echocollect est une passerelle dédiée à l’intégration des données “Process Data” vers des systèmes de hauts niveaux ou de solutions IoT.

La passerelle echocollect -e est une passerelle multi protocoles fournissant des solutions de managment “Process Data”. Elle offre des connexions “temps réel” entre PLC et bases de données,  OPC UA et OPC Classic connectivité. Ses fonctionnalités inclues à la fois le log de données locales et une intégration directe de données d’applications Cloud IoT via MQTT

 

 

Vous ne connaissez pas l’ echocollect ???

Présentation Echocollect  ( PDF )

Integration of Existing Systems in New Quality Assurance Systems

  • Independent real-time collection of manufacturing, process or quality data directly from programmable logic controllers (PLC) and delivery to higher-level management systems, such as ERP or MES system
  • Recipe manager functionality for writing data blocks to PLCs
  • Direct connectivity via SQL database protocols, platform independent OPC UA technology or MQTT Publisher functionality
  • Support of more than 50 PLC types addressable via Ethernet

Excellent Data and Network Security

  • Buffering of arriving data and addition of time stamps in case of broken connections, automatic forwarding once connection has been reestablished
  • Option for parallel data logging on SD card for traceability reasons
  • Physical network separation between production systems and commercial IT networks
  • State-of-the-art OPC UA security: Optional encryption of transmitted data and authentication via certificates

Lowered IT Maintenance Costs and Investment Protection

  • echocollect as standard component, addition of extra functionality without modifying existing systems
  • No need for additional PC requiring software updates and administration
  • Working for years once configured – untouched, without updates and with zero maintenance costs
  • Plug-and-go replacement, if necessary, using configuration stored on SD card
  • Very easy configuration by straightforward project import without requiring PLC modifications and programming skills

Easy Live Data Visualization

  • Native web technology for easy and cost-efficient visualization of process, manufacturing and quality data using standard web browser without any plug-ins
  • No need for OPC Server or complex SCADA system
  • Scalable, resolution-independent vector graphics for consistent display of data on wide variety of network enabled devices like desktop PCs, laptops, smart phones, tablet PCs or industrial control panels
Ethernet Addressable ControllersSiemens SIMATIC S7 and S5, controllers with Modbus TCP (Wago, Beckhoff, Phoenix Contact, Schneider Electric, etc.), Mitsubishi (Melsec-Q), etc.
Ethernet ProtocolsTCP/IP, RFC1006 (ISO on TCP), ISO (H1), S5, S7, TCP/IP with PLC header, Modbus TCP, Melsec-Q, raw data
Ethernet Interfaces2 x independent interfaces TP (RJ45), 10/100 MBit/s
Embedded OPC UA ServerSymbolic Mapping; Browsing, Read, Write, Subscribe; Self-Discovery Service; possible reconfiguration without device restart; possible multiple Client connections, optional read-only PLC connection; OPC UA Security with password or certificates
Embedded MQTT PublisherEstablishment of MQTT Broker connection, optional user authentication and data encryption, easy topic generation from existing symbols, maximum of 1,000 topics, adjustable publishing interval
Supported DatabasesMySQL, Oracle, DB2, MS-SQL
Other ProtocolsTelnet, SMTP (email notification), OPCpipe (OPC Tunnel)
Supported Engineering Tools for Symbol ImportSIMATIC STEP 7, TIA Portal
LimitationMaximum of 5 PLC connections, 10,000 items in total
Data mapping PLC – database must be structured in 400 tables and 200 items per table
Visualizationatvise webMI visualization, functional level ‘Advanced’ (fully event-driven data exchange) Limited to up to 50 visualized items per echocollect (optional upgrade possible), maximum of 5 simultaneously accessing browsers
Configuration SoftwareSofting NetCon for device configuration, atvise builder for SCADA project editing, dataFEED Exporter for symbol import
Power Supply24 VDC, ca. 0,3 A
Ambient ConditionsOperating temperature: 0 °C … 55 °C, storage temperature: -20 °C … 70 °C
Dimensions (HxWxL)131mm x 47mm x 111mm
Weightca. 0,4 kg
Mounting35 mm DIN Rail
Protection ClassIP20
CertificationsCE
GAL-YY-143101echocollect e (connectors: 2 x Ethernet, 1 x TTY)
LRA-YY-143001Upgrade echocollect: License for database access to Oracle, DB2 and MSSQL (default: MySQL only)
LRA-YY-143002Upgrade echocollect: License enabling data logging on SD Card (default: no data logging)
LRA-YY-143004Upgrade echocollect: License supporting unlimited number of visualization items (default: maximum of 50 visualization items)
LRA-YY-143005Upgrade echocollect: License embedded OPC UA Server (default: no embedded OPC UA Server)
LRA-YY-143007Upgrade echocollect: License MQTT Publisher functionality (default: no MQTT support)
LRA-YY-143115Upgrade echocollect: License enabling maximum of 15 PLC connections (default: maximum of 5 PLC connections)

Additional Products and Services

700-5596-04AC Adapter, 24 VDC, Euro, UK, or USA
LRL-DY-131701OPCpipe client
MEA-YY-144002CD atvise elements, 4,000 high-quality bitmaps and vector graphics in SVG format
GPL-CS-191000echolink sS7-compact
110-1000-01Industrial Ethernet – Troubleshooting in Automation, 3 days

Scope of Delivery

HardwareMulti-protocol gateway echocollect e, SD card, connector for power supply*
SoftwareNet configuration software on CD-ROM, also downloadable from Softing website
DocumentationQuick Start leaflet, context-based online help, CD-ROM with product handbook and configuration tutorials, also downloadable from Softing website

Connector Power Pack 24 V DC

Country-specific connector power packs are available. Note: A connector power pack is not included in the delivery of the echocollect. If necessary please order it separately.

Technical Details

100 – 240 V AC, 47 – 63 Hz, sec. 24 V, 1,25A

Order Number

Version EURO, UK, USA
700-5596-04

Which cloud platforms are supported?

We support with all Softing gateways (echocollect, uaGate, edgeGate) the Microsoft Azure Cloud, Amazon AWS Cloud, IBM Bluemix Cloud and other cloud providers, which are using MQTT for telemetry data.

What is the size of the Store & Forward queue on the echocollect?

The S&F queue for MQTT is unlimited (except the size of the sd-card). The echo buffers in the ram, and after it collects a bunch of messages, they were copied to the sd-card. To use the S&F feature, QoS 1 or QoS 2 must be used.

Les personnes intéressées par ce produit, peuvent être intéressées par :