Responsive Menu
Add more content here...
Ateva Technologies

Smartlink HW-DP

Connection

Asset Management and Parameterization of HART devices

Asset Management and Parameterization of PROFIBUS Devices

Direct Access to Process data from your PROFIBUS Network

Description

SmartLink DP for asset Management Access Point on PROFIBUS DP networks

smartlink DP

Connection of PROFIBUS and HART devices to HART IP, OPC UA, MQTT and FDT

smartLink HW-DP provides PLC independent access to PROFIBUS DP Networks. It enables Plant Asset Management for field devices using standard industry tools and allows using HART IP as a standardized format. smartLink HW-DP is a compact tool that can be integrated without interfering with the operation of existing installations. Thus, it enables Industry 4.0 connectivity for new and existing PROFIBUS DP networks.

smartLink DP

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Independent of configuration tools
  • Centralized and time-saving parameterization of PROFIBUS and HART field devices directly from the control room
  • Access from Plant Asset Management applications for field devices configuration based on FDT / DTM and EDDL standards (acyclic master)

Ethernet Access Point to PROFIBUS DP

  • Provides 2nd channel to access the field devices
  • Acts as PROFIBUS DP master class 2
  • Support of one PROFIBUS DP segment

Key Component for Transition to State-of-the-Art Technology

  • Re-use of existing PROFIBUS segments without requiring modification
  • Access to cyclic and acyclic data via HART-IP and OPC UA

Asset Management and Parameterization of HART Devices

Configuration, Parameterization, Plant Asset Management

  • Secure, standardized access to devices
  • Parallel to and independent of the controller

Inexpensive and low-risk integration

  • Connection of a large number of HART devices without rewiring the devices
  • Use of existing infrastructure using „HART over PROFIBUS“
  • Large number of supported Remote IOs

Compatible with established standard applications

  • Uses HART-IP as standard application protocol
  • Proven and tested with Emerson AMS Device Manager, ABB FIM, E+H FieldCare and PACTware

Asset Management and Parameterization of PROFIBUS Devices

Configuration, Parameterization, Plant Asset Management

  • Secure, standardized access to devices
  • Parallel to and independent of the controller

Compatible with established standard applications

  • Drivers available for FDT
  • Proven and tested with E+H FieldCare and PACTware

Direct Access to Process Data from PROFIBUS Networks

Capturing process data directly from the network

  • Live provision of all process data for further use in typical Industry 4.0 applications such as data analytics
  • Collecting data directly from the network, replacing the need to access the controller
  • No intervention in the running process

Secure provision of data using OPC UA

  • State-of-the-art transmission method in industrial networks
  • Fast update cycles over OPC UA possible

Asset Monitoring and Diagnostics in PROFIBUS Networks

Complete inventory of the entire network

  • I&M data from all connected devices
  • Automated live queries without configuration

Secure provision of data using MQTT

  • State-of-the-art transmission method for cloud connectivity
  • Information model based on OPC UA Companion Specifications for PROFINET

Health monitoring of all connected devices

  • Diagnostic messages and status of all bus stations
  • Statistics parameters for the entire network

Integrated with Softing plantPerfect Monitor application

  • Use the plantPerfect Monitor application to monitor the network with all its devices

 

 

Scope of Delivery
HardwaresmartLink HW-DP
DocumentationOn Website

 

Order Numbers
GEA-YN-026000smartLink HW-DP
GEA-YN-026001smartLink HW-DP 50, Hardware preloaded with licenses for 50 devices
GEA-YN-026002smartLink HW-DP 100, Hardware preloaded with licenses for 100 devices
GEA-YN-026003smartLink HW-DP 250, Hardware preloaded with licenses for 250 devices
GEA-YN-026004smartLink HW-DP 375, Hardware preloaded with licenses for 375 devices
LRA-NN-027004smartPlus DP, License access to one field device

 

Additional Products and Services
DBA-KM-020410mobiLink – Mobile HART interface
LRL-TG-020000plantPerfect Monitor, perpetual licence including 1 year software updates for 1 device
LMA-TG-020000plantPerfect Monitor, 1 year software updates for 1 device
LAA-TG-020000plantPerfect Monitor, 1 year rental licence for 1 device
smartLink HW-DP
HardwareProcessorIntel Cyclone V SoC with dual-core ARM Cortex-A9
Status LEDs (Gateway)PWR, RUN, ERR, BUS
Real-Time ClockReal-Time clock with buffering, setting the time via browser or by NTP server (buffer time depends on conditions such as ambient temperature and duration of use)
InterfacesEthernet1 x IEEE802.3 10BASE-T/100BASE-TX/1000BASE-T, Connector: RJ45
PROFIBUS DP1 x Segment with RS485 Physical Layer, Connector: 9-pin Sub-D socket
SupportedCommunication ProtocolsHART-IP, MQTT, OPC UA, PROFIBUS DP
PROFIBUS Remote IOsSiemens:
ET 200SP: 155-6BU01-0CN0
ET 200iSP: 152-1AA00-0AB0
ET 200M: 153-2BA10-0XB0
ABB:
S800: CI801, CI840, CI840A
S900: CI920N, CI920S
Pepperl+Fuchs:
LB: LB8105, LB8106, LB8109
FB: FB8206, FB8209
R.Stahl: iS1+: CPM 9440/15-01-11
Turck:
BL20: BL20-E-GW-DP, BL20-GW-DPV1
excom: GDP 1,5
WAGO: I/O System 750: 750-333, 750-833
HART IO ModulesSiemens:
ET 200SP: 134-6TD00-0CA1, 135-6TD00-0CA1
ET 200iSP: 134-7TD00-0AB0, 135-7TD00-0AB0, 134-7TD50-0AB0, 138-7FA00-0AB0
ET 200M: 332-8TF01-0AB0, 331-7TF00-0AB0, 331-7TF01-0AB0, 331-7TB00-0AB0, 332-8TF00-0AB0
ABB:
S800: AI815, AO815, AI845, AO845A, AI895, AO895
S900: AI930N, AO930N
Pepperl+Fuchs:
LB: LB3002, LB3102, LB3103, LB3105, LB4002, LB4005, LB4102, LB4105, LB3005A2, LB3006A, LB3106A, LB4106A, LB7104A
FB: FB3202B1, FB3202B2, FB3205B2, FB3205B3, FB3302B2, FB3305B2, FB4202B2, FB4202B3, FB4205B2, FB4205B3, FB4205C2, FB4302B2, FB7204B3, FB7304B3
R.Stahl: iS1+: AIM 9461/12-08-11, AOM 9466/12-08-11, AUM 9468/32-08-11
Turck:
BL20: BL20-2AIH-I, BL20-2AOH-I
excom: AIH40Ex, AOH40Ex
WAGO: I/O System 750: 750-484, 75x-842
HART-IP ApplicationsEmerson AMS Device Manager V14.1.1, V14.5
Endress + Hauser Netilion (FieldEdge SGC500)
ABB FIM V3.01
FDT ApplicationsPACTware, Endress + Hauser FieldCare
Physical PropertiesDimensions (H x W x D)120 mm x 28 mm x 110 mm
WeightApprox. 430g
Power Supply18 VDC … 32 VDC; SELV/PELV power supply mandatory
Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on)
Typical Power Loss5 W
Operating Temperature-40 °C … +65 °C (see detailed mounting description in user manual)
Storage Temperature-40 °C … +85 °C
Relative Humidity10 % … 95 %, non-condensing
CoolingConvection, no fan
MountingDIN rail 35 mm
Protection ClassIP20
Conformity / StandardsCEElectromagnetic compatibility (EMC) and Restriction of Hazardous Substances (RoHS)
EN 61000-6-2 Generic standards – Immunity standard for industrial environments
EN 61000-6-4 Generic standards – Emission standard for industrial environments
EN 55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements Class A
EN 55011 Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics –
Limits and methods of measurement Class A
EN IEC 63000:2018 RoHS, Assessment to the restriction of hazardous substances
FCCFCC 47 CFR Part 15B Section 15.109 (Class A)
VCCIVCCI Voluntary Control Council for Interferences by Information Technology Equipment, April 2015
EUR
EUREuro